EasyAlarm MINI

Schema des kompakten Aufzugsnotrufgeräts nach EN81-28 und EN81-70
Compact elevator emergency call device according to EN81-28 and EN81-70

Additional details

  • Voice connection at the touch of a button and door opening with tone dial 5 or 7 during the telephone connection.
  • The Implus duration of the door opening is adjustable.

  • Door Contact Signal Input =  Abuse Suppression
    If a signal change occurs during the pre-alarm time (=max. travel time), the emergency call is canceled.
  • External EN81-70 symbols
    Alternatively to the internal LEDs with light conductors can also be connected external symbols (max 400mA).
  • Accessory socket, e.g. for the connection of an  additional auxiliary intercom on/in the cabin.
                     

EA-MINI-V-MR (with 12s announcement function)
Order no: 100.0926
EA-MINI-V-MR-WG (with 12s announcement function, water protected)
Order no: 100.0927WG
MINI-MR-KSP (Telenot design)
Order no: 100.0946













Compact elevator emergency call device according to EN81-28 and EN81-70 for price-conscious people
2 in 1 - alarm device and door station

Door station Speech connection at the touch of a button and door opening with tone dialing 5 or 7 during the telephone connection.
The EA-Mini is conveniently configurable via the wall telephone, by remote call or the Leitronic online portal.

Alarm device e.g. for vestibules of elevators or airlocks with entrapment hazard or elevator emergency call with integrated misuse suppression: alarm is triggered if the door status signal does not change during the defined alarm filter time

Analog dialer (optionally expandable with GSM) Up to eight devices on one trunk line to save costs.

Conformity

  • 2014/30/EU, EN81-28:2018, EN81-70:2021, EN81-72:2020

Declaration of Conformity

Phone numbers

  • 1 .. 8: Alarm numbers
  • 9: Routine call (72h)

More functions

  • Remote programming
  • Remote dial-in (with/without) PIN code
  • Abuse suppression (door change)
  • Remote switching function (door opening = Doorphone)

Identification

  • PIN code (i.e. elevator number)
  • Individual announcement text (12s): Voice option

Protocols

  • WinMOS®300 
  • P100

Power supply

  • 6 - 24 V DC / 0.5 W Standby / 1.5 W max.

Housing

  • ABS black / 112 x 56 x 21 mm (L x W x D)

Engine room telephone

Telephone cable 3 m (other lengths on request) (RJ11<->end sleeves)
For programming locally and/or as machine room connection.

Order no: 118.0120

Surface-mounted protective housing with emergency call button EA-IP-EN70-EC

Protective housing for sub-stations EA-LMK70 / EA-LMC70 / Nano / Mini
Dimensions: 180x110x64 mm
Material: Housing BS
Protection class (EN 60529): IP 65


incl. emergency call button RT42 (bell raised) + connecting wires.
Order no: 100.0730

incl. emergency call button RT42 (bell raised) + terminals
Order no: 100.0730K

Front panels for microphone units

Retrofit front panels with and without emergency call buttons made of Inox or polycarbonate:

  • Surface and flush mounting possible
  • Advantage polycarbonate: Emergency light shines through
  • Emergency call buttonsAdapter EA-NT-IN
  • SNEL retrofit KIT (with hole pattern)
  • Hole pattern suggestions for new panels.
Detailed info sheet

Transparent front panel frame

Order no: 100.0231

Suitable for this:

  • Inox front panel EA-TAB | without emergency call button | Order no: 100.0220
  • Inox front panel EA-TAB-NT | incl. emergency call button RT-42 2M / Typ XI  | Order no: 100.0221
  • Inox front panel EA-TAB-HK | incl. Help is coming indicator RA-42 | Order no: 100.0222
  • Inox front panel EA-TAB-EN72 | incl. RT-42 2M speech button / type XI | Order no: 100.0223
  • Emergency LED chain 10cm  | inserted in recess below or above | Order no: 100.0870
  • Emergency light LED chain 2x10cm | inserted in recess below and above | Order no: 100.0873

Gateway DIN or IP version

The gateway simulates the analog telephone line.
Application: Exchange line replacement/operation during construction
Backup: 12 V battery
Connections: Telephone / Power Supply / Ready:Screw terminals / Emergency light output
Indications: Field strength with LED
Network: LTE/UMTS/GSM

IP version. - Order no: 100.0802BL
IP Light version - Order no: 100.0801BL
DIN version - Order no: 100.0812BL
DIN Light version - Order no: 100.0811BL

To the product page

Adapter board EA-LMK-ETMA-TRI

Enables quick and easy conversion of current Schindler panels with integrated ETMA elevator emergency call system to the EA-MINI

Order no.: 118.0172

Information sheet ETMA

LED emergency light 10cm, self-adhesive

LED chain 10cm self-adhesive | suitable for transparent front panel frame, Order no: 100.0231

techn. data: 12 V DC +/- 15% / 0.8 W / 52 lm (16 cd 120°)
Dimension: 117 x 9 x 9 mm (L x W x H)
Connections: Plug/screw terminal

Order no: 100.0870


LED emergency light 2x10cm, self-adhesive

LED emergency light 2x 10cm, self-adhesive | suitable for transparent frame Art. No: 100.0231
For both recesses of the transparent frame (light below and above)
Technical data: 12 V DC +/- 15% / 1.6 W / 104 lm (16 cd 120 °)
Dimensions: (100+117) x 9 x 9 mm (L x W x H)
Connections: Plug/screw terminal

Order no: 100.0873

LED screw IP67

Techn. data: 12 V DC +/- 15% / 0.2 W / 4 lm (44 cd 20°)
Drill hole: M8
Cable: 25cm

Order no: 100.0872

LED module, self-adhesive

techn. data: 12 V DC +/- 15% / 1.2 W / 50 lm  
Dimension: 37 x 32 x 5 mm (L x W x H) also screw mounting possible
Cable: 8cm between the elements (delivery as chain possible)

Order no: 100.0874

LED ring

LED ring | suitable for polycarbonate front panels (Art. No.: 100.0211 / 0212 / 0213)
insert into the Rx42 recess

Technical data: 4 to 15 V DC / 1 W  
Dimension: 52 x 52 x 6 mm (L x W x H)

Order no: 100.087
9

Mains supply DIN adapter EA-ACDC-USV

suitable for feeding the slave station EA-LMx70 from 230V
fits EA-NSG

Input voltage: 230 V +- 15% / 50 Hz
Secondary: 14.3 V DC / 10 W
Dimensions: 17.5 x 93 x 68.5 mm(L x W x H) / DIN rail 1TE

Order no: 118.0117

Voltage converter DIN adapter EA-DCDC-USV

Voltage converter e.g. for EA-UMTS/GSM-DIN

Dimensions:     17.5 x 93 x 68.5 mm (L x W x H) / DIN rail 1TE
Primary voltage: 9 - 35 VDC
Output voltage: 14.3V / 10 W

Order no: 118.0119

Emergency power adapter EA-NSG-CPU

Extension to UPS in combination with DIN adapter and 12V lead-acid battery

Dimensions: 53 x 90 x 32 mm (L x W x H) / DIN rail 3TE
Input voltage: 14.3V / 10 W
12V charging voltage for lead-acid battery
12V output voltage for emergency call device (max. 500mA)
12V switched emergency light output (max. 300mA) e.g. for LED emergency light chains 100.087x

Order no: 100.0117CPU

12V lead battery

Voltage: 12 V DC
Capacity: 1.2 Ah

Order no: 100.0880

DIN holder for battery

Order no: 100.0881


Emergency power unit UPS12-CPU-IP

Emergency power connection print EA-NSG-CPU + DIN-rail power supply unit + 12V lead-acid battery completely installed in IP65 housing

Housing dimensions: 182 x 180 x 63 mm
Weight: 1100 g

Order no: 121.0117A

Switching output for EasyAlarm ELEVATOR | EXICALL EN70 | MINI

Retrofitting of a switching output to any paging stations.
Also works in combination with the Leitronic adapter board ETMA and ORONA as well as for the low-cost paging station LMC-70.

Order no.: 100.0257

Download info sheet

Abuse suppression EA-2DOOR

Misuse detection with two independent elevator doors
Connections: 2 times door signal input | 2 times connection to  EasyAlarm or intercom

Door signal input (2x): active 10 to 35 V DC, status display with LED
Dimensions: 35 x 90 x 30 mm (L x W x H) / DIN rail 2TE

Order no: 100.0260B

AB flash protection adapter

Protects the telephone input of the emergency call devices from voltages >150V and filters ADSL signals
The lightning protection adapter is at the same time a distributor for the connection of a machine room telephone (MR telephone) or the remote stations EA-LMK72.

Housing: DIN rail 3TE
Dimensions: 90 x 52 x 30 mm (L x W x H)
Connections: Screw terminals + RJ12 jacks

Order no: 100.0328

Emergency button adapter EA-NT-IN

For existing systems with a single-pole alarm contact for the alarm horn, EA-NT-IN can be used to provide isolation to the telephone network without changing keys.

Alarm input: 4.8 to 35 V DC / limited to 10 mA (in parallel with the alarm horn)
Output contact: max. 350 V/0.12 A max. 30 Ohm (on emergency input)
Isolation: 1.5 kV
Connections: Plug/screw terminals

Order no: 100.0250A (NC oder NO)

Feel free to contact us for a comprehensive ATEX consultation also for elevator emergency calls

Slave station: LMK70-ATEX Zone 0

The LMK70-ATEX sub-station enables alarm triggering via an external emergency call button and the following hands-free connection.
Protection class: II 1 G Ex ia IIC T4 Ga
Dimensions: 112 x 56 x 21 mm (L x W x H)

Order no: 121.0370

Slave station: LMK70-ATEX Zone 0/20

LMK70-ATEX Zone 0 installed in a protective housing for Zone 20 with integrated emergency call button

Protection class: 
II 1 GD Ex ia IIC T4 Ga
Ex ia IIIC T50 °C Da IP64

Dimensions:
160 x 160 x 91 mm (L x W x H)
188 x 160 x 109 mm (L x W x H) PG11 + Button

Order no: 121.0380

ATEX Barrier outside ATEX zone

Power supply: 8 - 35V CC

Protection class:
II (1) GD[Ex ia Ga] IIC
[Ex ia Da] IIIC

Dimensions: 45 x 118 x 138 mm (L x W x H)

Order no: 121.0390

ATEX product page

Mobile radio connection and product alternative for elevator emergency call

We use cookies to ensure the usability of our website. You can "Accept All" or "Customize" individually.